Does Northern Ireland’s Class G allow an outdoor heat pump?
Class G permits an air source heat pump within the curtilage of a dwellinghouse when the conditions hold, including use to provide heat and MCS 020 Issue 1.3 at 42.0 dB(A) (SR 2015/70 as substituted by SR 2023/95, checked 25 Sep 2026). A flat is outside the class. A unit used only for cooling does not meet the heat condition.
computed
The Planning (General Permitted Development) Order (Northern Ireland) 2015 (SR 2015/70), Schedule, Part 2, Class G, as substituted by The Planning (General Permitted Development) (
Instrument checked 25 Sep 2026. Version 1.0.0.
| Point | Clause | Quote | Source | Version | Checked | In plain words | Input |
|---|---|---|---|---|---|---|---|
| NI-01 | Class G | The installation, alteration or replacement of an air source heat pump within the curtilage of a dwellinghouse. | www.legislation.gov.uk/nisr/2015/70/schedule/par | 1.0.0 | 25 Sep 2026 | Class G covers an air source heat pump within the curtilage of a dwellinghouse. A flat, or a building containing flats, is outside that class. | Is the building a house, or a building that is wholly flats? |
| NI-DWELL | article 2(1), 'dwellinghouse' | “ dwellinghouse ” does not include a building containing one or more flats, or a flat contained within such a building | www.legislation.gov.uk/nisr/2015/70/article/2 | 1.0.0 | 25 Sep 2026 | This row defines a term the other rows use. | No extra input — this row is a definition or a dataset note. |
| NI-02 | Class G.1(a) | it would result in the presence within the curtilage of more than one air source heat pump | www.legislation.gov.uk/nisr/2015/70/schedule/par | 1.0.0 | 25 Sep 2026 | Class G allows one air source heat pump within the curtilage. | How many outdoor units will the building have once this one is installed? |
| NI-03 | Class G.1(b) | any part of the air source heat pump would be installed within 1 metre of the boundary of the curtilage of another dwellinghouse | www.legislation.gov.uk/nisr/2015/70/schedule/par | 1.0.0 | 25 Sep 2026 | Any part of the unit within 1 m of another dwellinghouse's boundary is outside Class G. | How many metres from another house's boundary would the unit sit? |
| NI-04 | Class G.1(c) | any part of the air source heat pump would be situated on land forward of a wall which—(i) faces onto a road; and (ii) forms either the principal elevation or a side elevation of the original dwellinghouse | www.legislation.gov.uk/nisr/2015/70/schedule/par | 1.0.0 | 25 Sep 2026 | A unit forward of a road-facing principal or side wall of the original house is outside Class G. | Would it sit forward of the elevation that faces a road? |
| NI-05 | Class G.1(d) | in the case of a dwellinghouse within a World Heritage Site or conservation area any part of the air source heat pump faces onto and is visible from a road | www.legislation.gov.uk/nisr/2015/70/schedule/par | 1.0.0 | 25 Sep 2026 | In a conservation area or World Heritage Site, Class G does not cover a unit that faces a road and can be seen from it. | Is this exact address inside a conservation area?; Is this exact address in a World Heritage Site?; In a conservation area or World Heritage Site, would any part of the unit face a road and be visible from it? |
| NI-06 | Class G.1(e) | the external unit of the air source heat pump would exceed 3 metres in height | www.legislation.gov.uk/nisr/2015/70/schedule/par | 1.0.0 | 25 Sep 2026 | An external unit over 3 m high is outside Class G. | How tall would the resulting structure be, in metres? |
| NI-07 | Class G.1(f) | the air source heat pump would be installed on a roof | www.legislation.gov.uk/nisr/2015/70/schedule/par | 1.0.0 | 25 Sep 2026 | Class G does not cover a unit installed on a roof. | Is the unit mounted on a roof? |
| NI-08 | Class G.1(g) | the air source heat pump would be situated within the curtilage of a listed building unless listed building consent for the development has previously been granted | www.legislation.gov.uk/nisr/2015/70/schedule/par | 1.0.0 | 25 Sep 2026 | Within the curtilage of a listed building, Class G applies only where listed building consent has already been granted. | Is the building listed? A postcode search cannot clear this.; Has listed building consent already been granted for this unit? |
| NI-09 | Class G.2(a) | the air source heat pump would be used to provide heat for use within the curtilage of the dwellinghouse | www.legislation.gov.uk/nisr/2015/70/schedule/par | 1.0.0 | 25 Sep 2026 | Class G requires the pump to be used to provide heat. A unit used only for cooling does not meet that condition. A unit that heats and also cools is not excluded by these words. | Will the pump be used only for cooling, or for heating as well? |
| NI-10 | Class G.2(b) | when no longer used to provide heat it shall be removed as soon as reasonably practicable | www.legislation.gov.uk/nisr/2015/70/schedule/par | 1.0.0 | 25 Sep 2026 | When the pump is no longer used to provide heat, Class G says it is to be removed as soon as reasonably practicable. | No extra input — this row is a definition or a dataset note. |
| NI-11 | Class G.2(c) | the air source heat pump must comply with MCS planning standards or equivalent standards | www.legislation.gov.uk/nisr/2015/70/schedule/par | 1.0.0 | 25 Sep 2026 | Class G requires MCS 020 Issue 1.3, the 42.0 dB(A) method. The Order does not name the 37.0 dB MCS 020 a) limit. | What is the noise result at 1 m outside the neighbour's nearest habitable-room window? |
| NI-DEF | Class G.3, and SR 2023/95 footnote (4) | In Class G “ MCS Planning Standards ” means the product and installation standards for air source heat pumps specified in the Microgeneration Certification Scheme MCS 020. | www.legislation.gov.uk/nisr/2015/70/schedule/par | 1.0.0 | 25 Sep 2026 | This row defines a term the other rows use. | No extra input — this row is a definition or a dataset note. |
| NI-DATASET | n/a — no Northern Ireland conservation-area polygon in this snapshot | No statutory sentence is stored for this row. It records a gap in the geographic file, and a missing row is not a clearance. | www.communities-ni.gov.uk/publications/historic- | 1.0.0 | 25 Sep 2026 | There is no conservation-area polygon for this Northern Ireland council in the snapshot. That is not a clearance. | Is this authority covered by the planning dataset that was consulted? |
| mcs020_legacy_scotland | Step 10 | Is the FINAL RESULT in STEP 9 equal to or lower than the permitted development noise limit of 42.0 dB(A)? | www.midsussex.gov.uk/media/9082/mcs-020.pdf | 1.0.0 | 25 Sep 2026 | The noise limit in this method is 42.0 dB(A). Northern Ireland's Order names MCS 020 Issue 1.3, not MCS 020 a). | Sound power of the outdoor unit, distance to the neighbour’s window, and directivity Q. |
Next pages
The Planning (General Permitted Development) Order (Northern Ireland) 2015 (SR 2015/70), Schedule, Part 2, Class G, as substituted by The Planning (General Permitted Development) (Amendment) Order (Northern Ireland) 2023 (SR 2023/95), in fo · 25 Sep 2026 · n=15 · Each row is a point in docs/decision-contract.yaml. The engine that scores them is scripts/contract_engine.py. · updated 25 Sep 2026 · version 1.0.0 · CSV of the values on this page
Source detail