Does Northern Ireland’s Class G allow an outdoor heat pump?

Class G permits an air source heat pump within the curtilage of a dwellinghouse when the conditions hold, including use to provide heat and MCS 020 Issue 1.3 at 42.0 dB(A) (SR 2015/70 as substituted by SR 2023/95, checked 25 Sep 2026). A flat is outside the class. A unit used only for cooling does not meet the heat condition.

computed

Does Northern Ireland’s Class G allow an outdoor heat pump?

The Planning (General Permitted Development) Order (Northern Ireland) 2015 (SR 2015/70), Schedule, Part 2, Class G, as substituted by The Planning (General Permitted Development) (

Instrument checked 25 Sep 2026. Version 1.0.0.

Northern Ireland decision-contract points
PointClauseQuoteSourceVersionCheckedIn plain wordsInput
NI-01Class GThe installation, alteration or replacement of an air source heat pump within the curtilage of a dwellinghouse.www.legislation.gov.uk/nisr/2015/70/schedule/par1.0.025 Sep 2026Class G covers an air source heat pump within the curtilage of a dwellinghouse. A flat, or a building containing flats, is outside that class.Is the building a house, or a building that is wholly flats?
NI-DWELLarticle 2(1), 'dwellinghouse'“ dwellinghouse ” does not include a building containing one or more flats, or a flat contained within such a buildingwww.legislation.gov.uk/nisr/2015/70/article/21.0.025 Sep 2026This row defines a term the other rows use.No extra input — this row is a definition or a dataset note.
NI-02Class G.1(a)it would result in the presence within the curtilage of more than one air source heat pumpwww.legislation.gov.uk/nisr/2015/70/schedule/par1.0.025 Sep 2026Class G allows one air source heat pump within the curtilage.How many outdoor units will the building have once this one is installed?
NI-03Class G.1(b)any part of the air source heat pump would be installed within 1 metre of the boundary of the curtilage of another dwellinghousewww.legislation.gov.uk/nisr/2015/70/schedule/par1.0.025 Sep 2026Any part of the unit within 1 m of another dwellinghouse's boundary is outside Class G.How many metres from another house's boundary would the unit sit?
NI-04Class G.1(c)any part of the air source heat pump would be situated on land forward of a wall which—(i) faces onto a road; and (ii) forms either the principal elevation or a side elevation of the original dwellinghousewww.legislation.gov.uk/nisr/2015/70/schedule/par1.0.025 Sep 2026A unit forward of a road-facing principal or side wall of the original house is outside Class G.Would it sit forward of the elevation that faces a road?
NI-05Class G.1(d)in the case of a dwellinghouse within a World Heritage Site or conservation area any part of the air source heat pump faces onto and is visible from a roadwww.legislation.gov.uk/nisr/2015/70/schedule/par1.0.025 Sep 2026In a conservation area or World Heritage Site, Class G does not cover a unit that faces a road and can be seen from it.Is this exact address inside a conservation area?; Is this exact address in a World Heritage Site?; In a conservation area or World Heritage Site, would any part of the unit face a road and be visible from it?
NI-06Class G.1(e)the external unit of the air source heat pump would exceed 3 metres in heightwww.legislation.gov.uk/nisr/2015/70/schedule/par1.0.025 Sep 2026An external unit over 3 m high is outside Class G.How tall would the resulting structure be, in metres?
NI-07Class G.1(f)the air source heat pump would be installed on a roofwww.legislation.gov.uk/nisr/2015/70/schedule/par1.0.025 Sep 2026Class G does not cover a unit installed on a roof.Is the unit mounted on a roof?
NI-08Class G.1(g)the air source heat pump would be situated within the curtilage of a listed building unless listed building consent for the development has previously been grantedwww.legislation.gov.uk/nisr/2015/70/schedule/par1.0.025 Sep 2026Within the curtilage of a listed building, Class G applies only where listed building consent has already been granted.Is the building listed? A postcode search cannot clear this.; Has listed building consent already been granted for this unit?
NI-09Class G.2(a)the air source heat pump would be used to provide heat for use within the curtilage of the dwellinghousewww.legislation.gov.uk/nisr/2015/70/schedule/par1.0.025 Sep 2026Class G requires the pump to be used to provide heat. A unit used only for cooling does not meet that condition. A unit that heats and also cools is not excluded by these words.Will the pump be used only for cooling, or for heating as well?
NI-10Class G.2(b)when no longer used to provide heat it shall be removed as soon as reasonably practicablewww.legislation.gov.uk/nisr/2015/70/schedule/par1.0.025 Sep 2026When the pump is no longer used to provide heat, Class G says it is to be removed as soon as reasonably practicable.No extra input — this row is a definition or a dataset note.
NI-11Class G.2(c)the air source heat pump must comply with MCS planning standards or equivalent standardswww.legislation.gov.uk/nisr/2015/70/schedule/par1.0.025 Sep 2026Class G requires MCS 020 Issue 1.3, the 42.0 dB(A) method. The Order does not name the 37.0 dB MCS 020 a) limit.What is the noise result at 1 m outside the neighbour's nearest habitable-room window?
NI-DEFClass G.3, and SR 2023/95 footnote (4)In Class G “ MCS Planning Standards ” means the product and installation standards for air source heat pumps specified in the Microgeneration Certification Scheme MCS 020.www.legislation.gov.uk/nisr/2015/70/schedule/par1.0.025 Sep 2026This row defines a term the other rows use.No extra input — this row is a definition or a dataset note.
NI-DATASETn/a — no Northern Ireland conservation-area polygon in this snapshotNo statutory sentence is stored for this row. It records a gap in the geographic file, and a missing row is not a clearance.www.communities-ni.gov.uk/publications/historic-1.0.025 Sep 2026There is no conservation-area polygon for this Northern Ireland council in the snapshot. That is not a clearance.Is this authority covered by the planning dataset that was consulted?
mcs020_legacy_scotlandStep 10Is the FINAL RESULT in STEP 9 equal to or lower than the permitted development noise limit of 42.0 dB(A)?www.midsussex.gov.uk/media/9082/mcs-020.pdf1.0.025 Sep 2026The noise limit in this method is 42.0 dB(A). Northern Ireland's Order names MCS 020 Issue 1.3, not MCS 020 a).Sound power of the outdoor unit, distance to the neighbour’s window, and directivity Q.

The Planning (General Permitted Development) Order (Northern Ireland) 2015 (SR 2015/70), Schedule, Part 2, Class G, as substituted by The Planning (General Permitted Development) (Amendment) Order (Northern Ireland) 2023 (SR 2023/95), in fo · 25 Sep 2026 · n=15 · Each row is a point in docs/decision-contract.yaml. The engine that scores them is scripts/contract_engine.py. · updated 25 Sep 2026 · version 1.0.0 · CSV of the values on this page

Source detail

https://www.legislation.gov.uk/nisr/2015/70/schedule/part/2

Report an error on this page