UK home cooling

Home / Noise tool

Foursun FAC (F-A/C01-12V / FAC0112V) — will it pass the neighbour noise test?

At 3 m from your neighbour's window it gives ≈22.5 dB(A) — under England's 37 dB(A) limit; at 5 m it passes (≈18.0). Manufacturer-declared 40 dB(A). £ per summer is not scored: this registration has no cooling capacity and no SEER to divide it by. Tariff on file is 26.32p/kWh.

pass

Already calculated for one unit, Q=2, no barrier

  • 1 m · ≈32.0 dB(A) · pass
  • 3 m · ≈22.5 dB(A) · pass
  • 5 m · ≈18.0 dB(A) · pass
  • 8 m · ≈14.0 dB(A) · pass
  • 12 m · ≈10.4 dB(A) · pass
line · Foursun FAC (F-A/C01-12V / FAC0112V) · estimated sound pressure · ≈22.5 dB(A) at 3 m vs 37.0 dB(A) MCS 020a · checked 2026-09-25
Estimated sound pressure for Foursun FAC (F-A/C01-12V / FAC0112V) at Q=2 and Q=4, one unit, no barrier. Scotland is assessed at 1 m only.
DistanceQ=2 dB(A)Q=2 verdictWithin 2.0 dBQ=4 dB(A)Q=4 verdict
132.0passno35.0pass
322.5passno25.5pass
518.0passno21.0pass
814.0passno17.0pass
1210.4passno13.4pass
Scotland 1 m41passyes—Scottish legal point is 1 m, so Q=4 is not a second legal column here

EPREL https://eprel.ec.europa.eu/screen/product/airconditioners/2846465 · 2026-09-25 · n=1 · MCS 020a Issue 1.1 inverse-square formula via contract_engine, Q given, barrier none · updated 2026-09-25 · version 1.0.0 · CSV of the values on this page · class MOD-C01

MCS-020A-STEP8 · §3.2 Step 8 · checked 2026-09-25. If the calculated sound pressure level at all assessment positions is equal to or lower than 37.0 dB(A) then the heat pump will comply with the Permitted Development noise limit Source

Full engine wording and the measurement caveat

≈22.5 dB(A) at the assessment position (estimated by the MCS 020a method, manufacturer-declared LwA; not a measured level, proof of permitted development, or a guarantee against nuisance).

What cooling capacity is registered for this family?

Cooling capacity for Foursun FAC (F-A/C01-12V / FAC0112V) is pending_data — the EPREL row has no design load.

pending_data

Registered capacity. Room area is not converted.
FieldValueStatus
Cooling design load, kWpending_datapending_data

EPREL https://eprel.ec.europa.eu/screen/product/airconditioners/2846465 · 2026-09-25 · n=1 · value copied from the EPREL family row; no floor-area rule applied · updated 2026-09-25 · version 1.0.0 · CSV of the values on this page · class unmatched

Full engine wording and the measurement caveat

not a measured level, proof of permitted development, or a guarantee against nuisance

Do I need planning permission for this family in England, Wales or Scotland?

Class G is not a yes from the model card alone. Product class is portable1. On a house in England the outdoor unit has to be under 1.5 m³, meet 37 dB at the neighbour's window and stay off a road-facing wall in a conservation area; a block of flats is one unit up to 0.6 m³ (Class G as amended 29 May 2025, checked 25 Sep 2026). The address, the volume and the wall are what the planning check still needs.

address not supplied

Class G limits for a reversible unit. The address, volume and wall are still to enter.
NationResultStill to enterCited point
Englandnot_runproduct class is not an outdoor air-source heat pumpClass G, permitted development
Walesnot_runproduct class is not an outdoor air-source heat pumpClass G, permitted development
Scotlandnot_runproduct class is not an outdoor air-source heat pumpClass G, permitted development

https://www.legislation.gov.uk/uksi/2015/596/schedule/2/part/14 · 2026-09-25 · n=1 · evaluate_pd with building, volume, noise and siting left unknown · updated 2026-09-25 · version 1.0.0 · CSV of the values on this page · class PLN-C06

ENG-02 · G.1 · checked 2026-09-25. Development is not permitted by Class G unless the air source heat pump complies with the MCS Planning Standards. Source

Full engine wording and the measurement caveat

not a measured level, proof of permitted development, or a guarantee against nuisance

£ per summer at the price-cap tariff

£ per summer is not scored: this registration has no cooling capacity and no SEER to divide it by. Tariff on file is 26.32p/kWh.

not supplied

Scenario hours at 26.32p/kWh (Ofgem price cap, 2026-10-01 to 2026-12-31). Not a measured bill.
QuantityValueUnit
SEERnot on the registrationratio
Design loadnot on the registrationkW
Electrical drawnot scoredkW
£ per summer, 200 hnot scoredGBP
£ per summer, 400 hnot scoredGBP
£ per summer, 800 hnot scoredGBP

EPREL https://eprel.ec.europa.eu/screen/product/airconditioners/2846465 · 2026-09-25 · n=1 · kWh per hour ≈ design load ÷ SEER; not a measured bill · updated 2026-09-25 · version 1.0.0 · CSV of the values on this page · class unmatched

Full engine wording and the measurement caveat

not a measured level, proof of permitted development, or a guarantee against nuisance

What unit price was observed?

No dated unit price is stored for Foursun FAC (F-A/C01-12V / FAC0112V). Price status: pending_data. A median is not published from a missing price.

pending_data

Observed prices joined on the retail SKU. One row is not a median.
RetailerPrice GBPObservedSKU
pending_datapending_datapending_datapending_data

no retail observation · 2026-09-25 · n=1 · price copied from unit_prices_observed.csv; no inferred street price · updated 2026-09-25 · version 1.0.0 · CSV of the values on this page · class MOD-C10

Full engine wording and the measurement caveat

not a measured level, proof of permitted development, or a guarantee against nuisance

Does the £2,500 air-to-air grant attach to this family?

England and Wales: not supplied. £2,500 for air-to-air heat pumps (AAHP) (in residential properties only) (p.6 summary table, checked 2026-09-25). Scotland: not supplied. We will not cover: … Air to air heat pumps. (eligible costs, air-to-water/ground/water-to-water heat pump section, checked 2026-09-25). Home inputs that the engine still needs are listed with the verdict, not assumed.

not supplied

Grant engine by nation. Household predicates were not supplied.
NationEligibleWording
Englandnot suppliedCannot determine BUS eligibility — property_type is not known.
Walesnot suppliedCannot determine BUS eligibility — property_type is not known.
Scotlandnot suppliedCannot determine Home Energy Scotland eligibility without knowing the heat pump technology.

https://www.ofgem.gov.uk/sites/default/files/2026-07/boiler_upgrade_scheme_guidance_for_installers_v5.1_20260630135616-20260701135531.pdf · 2026-09-25 · n=1 · evaluate_grant; property_type left unknown; Scotland uses technology air_to_air only for air-to-air classes · updated 2026-09-25 · version 1.0.0 · CSV of the values on this page · class unmatched

BUS-amount · p.6 summary table · checked 2026-09-25. £2,500 for air-to-air heat pumps (AAHP) (in residential properties only) Source

Full engine wording and the measurement caveat

not a measured level, proof of permitted development, or a guarantee against nuisance

Which refrigerant is registered?

Registered refrigerant: R134a, GWP 1430 (EPREL, manufacturer-declared, checked 2026-09-25). No extra hazard class is added here beyond the registration.

computed

Refrigerant as registered. No hazard class is inferred.
FieldValue
RefrigerantR134a
GWP1430

EPREL https://eprel.ec.europa.eu/screen/product/airconditioners/2846465 · 2026-09-25 · n=1 · copied from the EPREL family row · updated 2026-09-25 · version 1.0.0 · CSV of the values on this page · class unmatched

Full engine wording and the measurement caveat

not a measured level, proof of permitted development, or a guarantee against nuisance

Better than a bare specification row: the neighbour-window distance is scored pass or fail against the MCS limit, with the clause and the check date.

Report an error in these figures