UK home cooling

Quietest 5 kW

Daikin FNA 5 kW: will it pass the neighbour noise test?

Over 37 dB at 3 m · clears from ≈6.3 m on a bracket (≈8.9 m against a wall)

At 3 m from next door's window this 5 kW unit gives ≈43.5 dB and it fails England's 37 dB limit. It clears the limit from about 6.3 m on a wall bracket (8.9 m if it stands on the ground against a wall). Outdoor sound power (LwA) 61 dB against 63 dB for 5 kW (1355 units). About £92.35 for a 400-hour summer, against about £78.21 typical. At 5 m on a bracket the calculated level is ≈39.0 dB and it fails.

£1,013 at Oceanair on 27 Sep 2026 — the unit, not fitting (fitted in London about £1,070–£3,746). Price seen for the shop code RXM50A+C001610, which matches 31 registrations (seasonal efficiency 5.7 / 5.8 / 5.9 / 6 / 6.1 / 6.3 / 6.5 / 7.2 / 7.3 / 7.4 / 7.6 / 7.8).

What this means for you. The 3 m here is an example. Move the metres to yours.

Will it pass at my distance

Measure from where the unit will hang to the middle of next door's nearest window. Scotland and Northern Ireland judge a heating-only installation at 1 m, with background noise included. At 1 m on a bracket this unit is about 54 dB on that heating route, against the 42 dB line. Cooling still needs an application there.

What this means for you. Use your metres, not the example.

What room is it for

Daikin UK's rule of thumb, used here as a sizing guide for any brand, is 0.1 kW per square metre at a 2.4 m ceiling. This 5 kW unit is about 50 m², or about 42 m² if the glass faces south or west. The rule does not add a separate loft figure.

What this means for you. A small bedroom can be less room than the rule asks for. That does not make the grant apply.

How many kW / BTU does this room need?

What a summer costs

Calculated, not a measured bill. Full power for the hours you pick, at 26.32 p/kWh.

£ per summer: this unit £46.18 / £92.35 / £184.70. The middle of the 5 kW class is £78.21 at 400 hours (cooling efficiency (SEER) 7). A 2.5 kW portable at efficiency 2.6 is £101.23.

What this means for you. The running cost is the small number. Fitting is the large one.

Buy and fit

One shop, one day: £1,013 at Oceanair on 27 Sep 2026. There is no median of several shops. Price seen for the shop code RXM50A+C001610, which matches 31 registrations (seasonal efficiency 5.7 / 5.8 / 5.9 / 6 / 6.1 / 6.3 / 6.5 / 7.2 / 7.3 / 7.4 / 7.6 / 7.8). Fitted in London, a one-room split is about £1,070–£3,746, an estimate from published guides, checked 25 Sep 2026.

Check the London cost page · Other regions

What this means for you. The shop price is the unit. Fitting is the larger range.

Planning

The outdoor unit is 0.29 m³ — under the 1.5 m³ limit for a house, under the 0.6 m³ limit for a flat, and under the 1 m³ limit for a flat in Wales. Checked 2026-09-27. The noise test and the wall are still separate.

EnglandA unit that heats and cools can be allowed without an application: under 1.5 m³ on a house, one unit under 0.6 m³ on a block of flats, under 37 dB, and off a street-facing wall in a conservation area.
WalesSame noise line, 37 dB. A block of flats is one unit under 1 m³.
ScotlandCooling needs an application. The heating-only route uses 42 dB at 1 m, background included. Cooling is not covered by that route.
Northern IrelandThe heating route uses 42 dB and is written for a house. The £2,500 grant does not apply. A BT postcode is not sent to a postcode directory.

What this means for you. Pick the postcode on the district page. This card cannot say yes on its own.

Grant

A bedroom unit is not the £2,500 grant. England and Wales, whole home: four questions about the heating, and confirmed MCS air-to-air installers today are 0. Scotland does not fund an air-to-air unit. Northern Ireland is outside that grant.

Does this air-to-air heat pump qualify for £2,500?

This model is an air-to-air heat pump, so the technology is already filled in. The four tests are about the home.

Answer the four questions

Certified path: MCS air-to-air 0 (checked 25 Sep 2026).

Ofgem Boiler Upgrade Scheme guidance: £2,500 for an air-to-air heat pump in a residential property. Checked 25 Sep 2026.

What this means for you. Do not subtract £2,500 from a bedroom quote.

Quieter or cheaper alternatives

None of the units with a shop price clears 37 dB at 3 m on a bracket.

What this means for you. Open a pair if you already have two model numbers.

Specs

Seasonal efficiency and the gas

Cooling efficiency (SEER) 5.7 — higher uses less electricity for the same cooling. Heating efficiency (SCOP) 4.1. Gas R-32, warming effect (GWP) 675 versus carbon dioxide. Maker's declared figures, checked 25 Sep 2026. Registration codes: FNA50A2VEB9, RXM50A5V1B8.

What this means for you. The efficiency is why the summer bill moves. It is not a noise figure.

Sources & method

Report an error on this page

Did you install one?

Installed

Answers are counted anonymously; totals appear here once three or more people have answered.