Daikin FBA 9.5 kW: will it pass the neighbour noise test?
Over 37 dB at 3 m · clears from ≈11.2 m on a bracket (≈15.9 m against a wall)
At 3 m from next door's window this 9.5 kW unit gives ≈48.5 dB and it fails England's 37 dB limit. It clears the limit from about 11.2 m on a wall bracket (15.9 m if it stands on the ground against a wall). Outdoor sound power (LwA) 66 dB against 69 dB for 10 kW (1637 units). About £149.28 for a 400-hour summer, against about £166.69 typical. At 5 m on a bracket the calculated level is ≈44.0 dB and it fails.
What this means for you. The 3 m here is an example. Move the metres to yours.
Will it pass at my distance
Measure from where the unit will hang to the middle of next door's nearest window. Scotland and Northern Ireland judge a heating-only installation at 1 m, with background noise included. At 1 m on a bracket this unit is about 59 dB on that heating route, against the 42 dB line. Cooling still needs an application there.
What this means for you. Use your metres, not the example.
What room is it for
Daikin UK's rule of thumb, used here as a sizing guide for any brand, is 0.1 kW per square metre at a 2.4 m ceiling. This 9.5 kW unit is about 95 m², or about 79 m² if the glass faces south or west. The rule does not add a separate loft figure.
What this means for you. A small bedroom can be less room than the rule asks for. That does not make the grant apply.
What a summer costs
Calculated, not a measured bill. Full power for the hours you pick, at 26.32 p/kWh.
£ per summer: this unit £74.64 / £149.28 / £298.56. The middle of the 10 kW class is £166.69 at 400 hours (cooling efficiency (SEER) 6.2). A 2.5 kW portable at efficiency 2.6 is £101.23.
What this means for you. The running cost is the small number. Fitting is the large one.
Buy and fit
No dated shop price is stored for this model.
Check the London cost page · Other regions
What this means for you. The shop price is the unit. Fitting is the larger range.
Planning
We don't have this unit's outdoor volume yet — the size test (1.5 m³ house, 0.6 m³ flat, 1 m³ for a flat in Wales) is open.
What this means for you. Pick the postcode on the district page. This card cannot say yes on its own.
Grant
A bedroom unit is not the £2,500 grant. England and Wales, whole home: four questions about the heating, and confirmed MCS air-to-air installers today are 0. Scotland does not fund an air-to-air unit. Northern Ireland is outside that grant.
What this means for you. Do not subtract £2,500 from a bedroom quote.
Quieter or cheaper alternatives
None of the units with a shop price clears 37 dB at 3 m on a bracket.
What this means for you. Open a pair if you already have two model numbers.
Specs
Seasonal efficiency and the gas
Cooling efficiency (SEER) 6.7 — higher uses less electricity for the same cooling. Heating efficiency (SCOP) 4.1. Gas R-32, warming effect (GWP) 675 versus carbon dioxide. Maker's declared figures, checked 25 Sep 2026. Registration codes: FBA35A2VEB9, RZAG100N7Y1B.
What this means for you. The efficiency is why the summer bill moves. It is not a noise figure.
Sources & method
- Outdoor sound power, efficiency and the gas come from this model's row in the EU energy-label register.
- Sound at the window: the site noise formula. A wall bracket is one reflecting surface, off the ground. On the ground against a wall is two. A corner is three.
- A brick wall between uses the worked example, minus 5 dB. A thin fence uses minus 2.5 dB in England and Wales. Scotland's heating route publishes one brick figure and no thin-fence figure, so a fence subtracts nothing there.
- Price, when shown, is one shop observation. London fitting: £1,070–£3,746.
- Cooling efficiency above 12 is left out of class medians (7 registrations). Checked 2026-09-25.