Nørdis NDIOE+NDIOP+NDIS 12.2 kW (FMA-42I5HD/DVO) vs Olimpia Splendid OSSENEH 12.3 kW (OS-CANMH42EI / OS-SENEH09EI): which is quieter and cheaper to run?

Olimpia Splendid OSSENEH 12.3 kW (OS-CANMH42EI / OS-SENEH09EI) is ≈1.0 dB quieter outside (passes England's 37 dB limit from 15.8 m vs 17.7 m for Nørdis NDIOE+NDIOP+NDIS 12.2 kW (FMA-42I5HD/DVO)); Olimpia Splendid OSSENEH 12.3 kW (OS-CANMH42EI / OS-SENEH09EI) costs ≈£8.22 less per summer at 400 hours and 26.32p/kWh. Pick Olimpia Splendid OSSENEH 12.3 kW (OS-CANMH42EI / OS-SENEH09EI) if the unit goes close to a neighbour's window; pick Nørdis NDIOE+NDIOP+NDIS 12.2 kW (FMA-42I5HD/DVO) if the running-cost figures matter more.

manufacturer-declared, EPREL

37 dB(A) 1 m2 m3 m4 m5 m8 m12 m
Nørdis NDIOE+NDIOP+NDIS 12.2 kW (FMA-42I5HD/DVO) and Olimpia Splendid OSSENEH 12.3 kW (OS-CANMH42EI / OS-SENEH09EI), estimated dB(A).

Where the registered figures differ

The marker that opened this page: lwa, seer, scop, pass_distance. Both columns use the same tariff and the same noise setting.

Nørdis NDIOE+NDIOP+NDIS 12.2 kW (FMA-42I5HD/DVO) against Olimpia Splendid OSSENEH 12.3 kW (OS-CANMH42EI / OS-SENEH09EI). Difference is left minus right.
FieldNørdis NDIOE+NDIOP+NDIS 12.2 kW (FMA-42I5HD/DVO)Olimpia Splendid OSSENEH 12.3 kW (OS-CANMH42EI / OS-SENEH09EI)DifferenceSource
Outdoor sound power70.0 dB(A)69.0 dB(A)+1.0 dBmanufacturer-declared, EPREL
SEER6.16.4−0.3 SEERmanufacturer-declared, EPREL
SCOP4.03.7+0.3 SCOPmanufacturer-declared, EPREL
RefrigerantR32R32samemanufacturer-declared, EPREL
GWP675675≈0 GWPmanufacturer-declared, EPREL
£ per summer, 400 h£210.56£202.34+£8.22calculated: capacity ÷ SEER × 400 h × price-cap rate
Distance to pass 37 dB≈17.7 m≈15.8 m+1.9 mcalculated, MCS 020a, Q=2, no barrier
Cooling capacity12.2 kW12.3 kW−0.1 kWmanufacturer-declared, EPREL

Sound at a neighbour's window

Each distance is one outdoor unit, Q=2, no barrier, scored against England and Wales at 37 dB(A).

Estimated sound pressure. Scotland's legal point is a different sum and is not this column.
DistanceNørdis NDIOE+NDIOP+NDIS 12.2 kW (FMA-42I5HD/DVO) dB(A)Nørdis NDIOE+NDIOP+NDIS 12.2 kW (FMA-42I5HD/DVO) vs 37 dBOlimpia Splendid OSSENEH 12.3 kW (OS-CANMH42EI / OS-SENEH09EI) dB(A)Olimpia Splendid OSSENEH 12.3 kW (OS-CANMH42EI / OS-SENEH09EI) vs 37 dB
1 m62.0over61.0over
2 m56.0over55.0over
3 m52.5over51.5over
4 m50.0over49.0over
5 m48.0over47.0over
8 m44.0over43.0over
12 m40.4over39.4over

EPREL manufacturer-declared registrations · snapshot 25 Sep 2026 · n=2 · pair source tier is the weaker of the two cards; noise via contract_engine MCS 020a Q=2, no barrier · updated 25 Sep 2026 · version 1.0.0 · CSV of the values on this page

How this page was calculated

If the calculated sound pressure level at all assessment positions is equal to or lower than 37.0 dB(A) then the heat pump will comply with the Permitted Development noise limit Estimated by MCS 020a Issue 1.1 for one unit, Q=2, no barrier, via contract_engine. £ per summer is capacity ÷ SEER × hours × 26.32p/kWh (2026-10-01 to 2026-12-31). The pair row lives in the compare index CSV.

Better than a spec-sheet glance: the gap is scored at the same distances against the 37 dB line, and £ per summer uses one tariff.