Mitsubishi Electric SEZM 5.6 kW (SUZ-KA60VA6) vs Mitsubishi Heavy Industries FDUM 5.6 kW (SRC60ZSX-W1): which is quieter and cheaper to run?

Mitsubishi Heavy Industries FDUM 5.6 kW (SRC60ZSX-W1) is better on every figure we have: SEER 1.0 higher, SCOP 0.3 higher and ≈£16.49 cheaper to run. Mitsubishi Electric SEZM 5.6 kW (SUZ-KA60VA6) only makes sense if it is cheaper where you buy it.

manufacturer-declared, EPREL

37 dB(A) 1 m2 m3 m4 m5 m8 m12 m
Mitsubishi Electric SEZM 5.6 kW (SUZ-KA60VA6) and Mitsubishi Heavy Industries FDUM 5.6 kW (SRC60ZSX-W1), estimated dB(A).

Where the registered figures differ

The marker that opened this page: seer, scop, refrigerant, gwp. Both columns use the same tariff and the same noise setting.

Mitsubishi Electric SEZM 5.6 kW (SUZ-KA60VA6) against Mitsubishi Heavy Industries FDUM 5.6 kW (SRC60ZSX-W1). Difference is left minus right.
FieldMitsubishi Electric SEZM 5.6 kW (SUZ-KA60VA6)Mitsubishi Heavy Industries FDUM 5.6 kW (SRC60ZSX-W1)DifferenceSource
Outdoor sound power65.0 dB(A)65.0 dB(A)≈0 dBmanufacturer-declared, EPREL
SEER5.56.5−1.0 SEERmanufacturer-declared, EPREL
SCOP4.14.4−0.3 SCOPmanufacturer-declared, EPREL
RefrigerantR410AR32differentmanufacturer-declared, EPREL
GWP1975675+1300 GWPmanufacturer-declared, EPREL
£ per summer, 400 h£107.19£90.70+£16.49calculated: capacity ÷ SEER × 400 h × price-cap rate
Distance to pass 37 dB≈10.0 m≈10.0 m≈0 mcalculated, MCS 020a, Q=2, no barrier
Cooling capacity5.6 kW5.6 kW≈0 kWmanufacturer-declared, EPREL

Sound at a neighbour's window

Each distance is one outdoor unit, Q=2, no barrier, scored against England and Wales at 37 dB(A).

Estimated sound pressure. Scotland's legal point is a different sum and is not this column.
DistanceMitsubishi Electric SEZM 5.6 kW (SUZ-KA60VA6) dB(A)Mitsubishi Electric SEZM 5.6 kW (SUZ-KA60VA6) vs 37 dBMitsubishi Heavy Industries FDUM 5.6 kW (SRC60ZSX-W1) dB(A)Mitsubishi Heavy Industries FDUM 5.6 kW (SRC60ZSX-W1) vs 37 dB
1 m57.0over57.0over
2 m51.0over51.0over
3 m47.5over47.5over
4 m45.0over45.0over
5 m43.0over43.0over
8 m39.0over39.0over
12 m35.4pass35.4pass

EPREL manufacturer-declared registrations · snapshot 25 Sep 2026 · n=2 · pair source tier is the weaker of the two cards; noise via contract_engine MCS 020a Q=2, no barrier · updated 25 Sep 2026 · version 1.0.0 · CSV of the values on this page

How this page was calculated

If the calculated sound pressure level at all assessment positions is equal to or lower than 37.0 dB(A) then the heat pump will comply with the Permitted Development noise limit Estimated by MCS 020a Issue 1.1 for one unit, Q=2, no barrier, via contract_engine. £ per summer is capacity ÷ SEER × hours × 26.32p/kWh (2026-10-01 to 2026-12-31). The pair row lives in the compare index CSV.

Better than a spec-sheet glance: the gap is scored at the same distances against the 37 dB line, and £ per summer uses one tariff.