Haier AS 3.3 kW (1U35MEPFRA-PRE) vs Panasonic CSUZ 3.3 kW (CU-UZ35WKE): which is quieter and cheaper to run?

Panasonic CSUZ 3.3 kW (CU-UZ35WKE) is ≈1.0 dB quieter outside (passes England's 37 dB limit from 8.9 m vs 10.0 m for Haier AS 3.3 kW (1U35MEPFRA-PRE)); Haier AS 3.3 kW (1U35MEPFRA-PRE) costs ≈£16.08 less per summer at 400 hours and 26.32p/kWh. Pick Panasonic CSUZ 3.3 kW (CU-UZ35WKE) if the unit goes close to a neighbour's window; pick Haier AS 3.3 kW (1U35MEPFRA-PRE) if running cost matters more.

manufacturer-declared, EPREL

37 dB(A) 1 m2 m3 m4 m5 m8 m12 m
Haier AS 3.3 kW (1U35MEPFRA-PRE) and Panasonic CSUZ 3.3 kW (CU-UZ35WKE), estimated dB(A).

Where the registered figures differ

The marker that opened this page: lwa, seer, scop, pass_distance. Both columns use the same tariff and the same noise setting.

Haier AS 3.3 kW (1U35MEPFRA-PRE) against Panasonic CSUZ 3.3 kW (CU-UZ35WKE). Difference is left minus right.
FieldHaier AS 3.3 kW (1U35MEPFRA-PRE)Panasonic CSUZ 3.3 kW (CU-UZ35WKE)DifferenceSource
Outdoor sound power65.0 dB(A)64.0 dB(A)+1.0 dBmanufacturer-declared, EPREL
SEER8.56.1+2.4 SEERmanufacturer-declared, EPREL
SCOP4.64.1+0.5 SCOPmanufacturer-declared, EPREL
RefrigerantR32R32samemanufacturer-declared, EPREL
GWP675675≈0 GWPmanufacturer-declared, EPREL
£ per summer, 400 h£40.87£56.95−£16.08calculated: capacity ÷ SEER × 400 h × price-cap rate
Distance to pass 37 dB≈10.0 m≈8.9 m+1.1 mcalculated, MCS 020a, Q=2, no barrier
Cooling capacity3.3 kW3.3 kW≈0 kWmanufacturer-declared, EPREL

Sound at a neighbour's window

Each distance is one outdoor unit, Q=2, no barrier, scored against England and Wales at 37 dB(A).

Estimated sound pressure. Scotland's legal point is a different sum and is not this column.
DistanceHaier AS 3.3 kW (1U35MEPFRA-PRE) dB(A)Haier AS 3.3 kW (1U35MEPFRA-PRE) vs 37 dBPanasonic CSUZ 3.3 kW (CU-UZ35WKE) dB(A)Panasonic CSUZ 3.3 kW (CU-UZ35WKE) vs 37 dB
1 m57.0over56.0over
2 m51.0over50.0over
3 m47.5over46.5over
4 m45.0over44.0over
5 m43.0over42.0over
8 m39.0over38.0over
12 m35.4pass34.4pass

EPREL manufacturer-declared registrations · snapshot 25 Sep 2026 · n=2 · pair source tier is the weaker of the two cards; noise via contract_engine MCS 020a Q=2, no barrier · updated 25 Sep 2026 · version 1.0.0 · CSV of the values on this page

How this page was calculated

If the calculated sound pressure level at all assessment positions is equal to or lower than 37.0 dB(A) then the heat pump will comply with the Permitted Development noise limit Estimated by MCS 020a Issue 1.1 for one unit, Q=2, no barrier, via contract_engine. £ per summer is capacity ÷ SEER × hours × 26.32p/kWh (2026-10-01 to 2026-12-31). The pair row lives in the compare index CSV.

Better than a spec-sheet glance: the gap is scored at the same distances against the 37 dB line, and £ per summer uses one tariff.