UK home cooling

Home / Haier AD 10 kW (1U105S2SS1F)

Haier AD 10 kW (1U105S2SS1F) vs Hitachi RAK 10 kW (RAM-110NP5E / RAK-25RXE): which is quieter and cheaper to run?

Haier AD 10 kW (1U105S2SS1F) costs ≈£8.63 less per summer at 400 hours and 26.32p/kWh. Pick Haier AD 10 kW (1U105S2SS1F) if running cost matters more; pick Hitachi RAK 10 kW (RAM-110NP5E / RAK-25RXE) if the neighbour-window figure matters more.

manufacturer-declared, EPREL

37 dB(A) 1 m2 m3 m4 m5 m8 m12 m
Haier AD 10 kW (1U105S2SS1F) and Hitachi RAK 10 kW (RAM-110NP5E / RAK-25RXE), estimated dB(A).

Where the registered figures differ

The marker that opened this page: seer, scop. Both columns use the same tariff and the same noise setting.

Haier AD 10 kW (1U105S2SS1F) against Hitachi RAK 10 kW (RAM-110NP5E / RAK-25RXE). Difference is left minus right.
FieldHaier AD 10 kW (1U105S2SS1F)Hitachi RAK 10 kW (RAM-110NP5E / RAK-25RXE)DifferenceSource
Outdoor sound power68.0 dB(A)68.0 dB(A)≈0 dBmanufacturer-declared, EPREL
SEER6.25.9+0.3 SEERmanufacturer-declared, EPREL
SCOP4.04.2−0.2 SCOPmanufacturer-declared, EPREL
RefrigerantR32R32samemanufacturer-declared, EPREL
GWP675675≈0 GWPmanufacturer-declared, EPREL
£ per summer, 400 h£169.81£178.44−£8.63calculated: capacity ÷ SEER × 400 h × price-cap rate
Distance to pass 37 dB≈14.1 m≈14.1 m≈0 mcalculated, MCS 020a, Q=2, no barrier
Cooling capacity10 kW10 kW≈0 kWmanufacturer-declared, EPREL

Sound at a neighbour's window

Each distance is one outdoor unit, Q=2, no barrier, scored against England and Wales at 37 dB(A).

Estimated sound pressure. Scotland's legal point is a different sum and is not this column.
DistanceHaier AD 10 kW (1U105S2SS1F) dB(A)Haier AD 10 kW (1U105S2SS1F) vs 37 dBHitachi RAK 10 kW (RAM-110NP5E / RAK-25RXE) dB(A)Hitachi RAK 10 kW (RAM-110NP5E / RAK-25RXE) vs 37 dB
1 m60.0over60.0over
2 m54.0over54.0over
3 m50.5over50.5over
4 m48.0over48.0over
5 m46.0over46.0over
8 m42.0over42.0over
12 m38.4over38.4over

EPREL manufacturer-declared registrations · snapshot 25 Sep 2026 · n=2 · pair source tier is the weaker of the two cards; noise via contract_engine MCS 020a Q=2, no barrier · updated 25 Sep 2026 · version 1.0.0 · CSV of the values on this page

How this page was calculated

If the calculated sound pressure level at all assessment positions is equal to or lower than 37.0 dB(A) then the heat pump will comply with the Permitted Development noise limit Estimated by MCS 020a Issue 1.1 for one unit, Q=2, no barrier, via contract_engine. £ per summer is capacity ÷ SEER × hours × 26.32p/kWh (2026-10-01 to 2026-12-31). The pair row lives in the compare index CSV.

Better than a spec-sheet glance: the gap is scored at the same distances against the 37 dB line, and £ per summer uses one tariff.