UK home cooling

Home / Fujitsu AUXG 8.5 kW (AOYG30LBTA / AUXG30LRLB)

Fujitsu AUXG 8.5 kW (AOYG30LBTA / AUXG30LRLB) vs Hitachi RAK 8.5 kW (RAM-90NYP5E / RAK-18RPE): which is quieter and cheaper to run?

Hitachi RAK 8.5 kW (RAM-90NYP5E / RAK-18RPE) is ≈1.0 dB quieter outside (passes England's 37 dB limit from 11.2 m vs 12.5 m for Fujitsu AUXG 8.5 kW (AOYG30LBTA / AUXG30LRLB)); Hitachi RAK 8.5 kW (RAM-90NYP5E / RAK-18RPE) costs ≈£7.52 less per summer at 400 hours and 26.32p/kWh. Pick Hitachi RAK 8.5 kW (RAM-90NYP5E / RAK-18RPE) if the unit goes close to a neighbour's window; pick Fujitsu AUXG 8.5 kW (AOYG30LBTA / AUXG30LRLB) if the running-cost figures matter more.

manufacturer-declared, EPREL

37 dB(A) 1 m2 m3 m4 m5 m8 m12 m
Fujitsu AUXG 8.5 kW (AOYG30LBTA / AUXG30LRLB) and Hitachi RAK 8.5 kW (RAM-90NYP5E / RAK-18RPE), estimated dB(A).

Where the registered figures differ

The marker that opened this page: lwa, seer, scop, refrigerant, gwp, pass_distance. Both columns use the same tariff and the same noise setting.

Fujitsu AUXG 8.5 kW (AOYG30LBTA / AUXG30LRLB) against Hitachi RAK 8.5 kW (RAM-90NYP5E / RAK-18RPE). Difference is left minus right.
FieldFujitsu AUXG 8.5 kW (AOYG30LBTA / AUXG30LRLB)Hitachi RAK 8.5 kW (RAM-90NYP5E / RAK-18RPE)DifferenceSource
Outdoor sound power67.0 dB(A)66.0 dB(A)+1.0 dBmanufacturer-declared, EPREL
SEER6.77.1−0.4 SEERmanufacturer-declared, EPREL
SCOP4.34.1+0.2 SCOPmanufacturer-declared, EPREL
RefrigerantR410AR32differentmanufacturer-declared, EPREL
GWP2088675+1413 GWPmanufacturer-declared, EPREL
£ per summer, 400 h£133.56£126.04+£7.52calculated: capacity ÷ SEER × 400 h × price-cap rate
Distance to pass 37 dB≈12.5 m≈11.2 m+1.3 mcalculated, MCS 020a, Q=2, no barrier
Cooling capacity8.5 kW8.5 kW≈0 kWmanufacturer-declared, EPREL

Sound at a neighbour's window

Each distance is one outdoor unit, Q=2, no barrier, scored against England and Wales at 37 dB(A).

Estimated sound pressure. Scotland's legal point is a different sum and is not this column.
DistanceFujitsu AUXG 8.5 kW (AOYG30LBTA / AUXG30LRLB) dB(A)Fujitsu AUXG 8.5 kW (AOYG30LBTA / AUXG30LRLB) vs 37 dBHitachi RAK 8.5 kW (RAM-90NYP5E / RAK-18RPE) dB(A)Hitachi RAK 8.5 kW (RAM-90NYP5E / RAK-18RPE) vs 37 dB
1 m59.0over58.0over
2 m53.0over52.0over
3 m49.5over48.5over
4 m47.0over46.0over
5 m45.0over44.0over
8 m41.0over40.0over
12 m37.4over36.4pass

EPREL manufacturer-declared registrations · snapshot 25 Sep 2026 · n=2 · pair source tier is the weaker of the two cards; noise via contract_engine MCS 020a Q=2, no barrier · updated 25 Sep 2026 · version 1.0.0 · CSV of the values on this page

How this page was calculated

If the calculated sound pressure level at all assessment positions is equal to or lower than 37.0 dB(A) then the heat pump will comply with the Permitted Development noise limit Estimated by MCS 020a Issue 1.1 for one unit, Q=2, no barrier, via contract_engine. £ per summer is capacity ÷ SEER × hours × 26.32p/kWh (2026-10-01 to 2026-12-31). The pair row lives in the compare index CSV.

Better than a spec-sheet glance: the gap is scored at the same distances against the 37 dB line, and £ per summer uses one tariff.

Report an error in these figures