Fujitsu ASEH 2 kW (AOEH07KNCA) vs Yolco TC (TC290): which is quieter and cheaper to run?

Fujitsu ASEH 2 kW (AOEH07KNCA) is ≈53.0 dB(A) outside and passes England's 37 dB limit from 2.5 m; Yolco TC (TC290) declares ≈62.0 dB(A) and has no outdoor unit. Pick Yolco TC (TC290) if you need no outdoor unit — Class G does not apply; pick Fujitsu ASEH 2 kW (AOEH07KNCA) if the neighbour-window figure matters more.

manufacturer-declared, EPREL

37 dB(A) 1 m2 m3 m4 m5 m8 m12 m
Fujitsu ASEH 2 kW (AOEH07KNCA) and Yolco TC (TC290), estimated dB(A).

Where the registered figures differ

The marker that opened this page: lwa, refrigerant, gwp, pass_distance. Both columns use the same tariff and the same noise setting.

Fujitsu ASEH 2 kW (AOEH07KNCA) against Yolco TC (TC290). Difference is left minus right.
FieldFujitsu ASEH 2 kW (AOEH07KNCA)Yolco TC (TC290)DifferenceSource
Declared sound power53.0 dB(A)62.0 dB(A)−9.0 dBmanufacturer-declared, EPREL
SEER7.8——manufacturer-declared, EPREL
SCOP4.4——manufacturer-declared, EPREL
RefrigerantR32R290differentmanufacturer-declared, EPREL
GWP6753+672 GWPmanufacturer-declared, EPREL
£ per summer, 400 h£26.99——calculated: capacity ÷ SEER × 400 h × price-cap rate
Distance to pass 37 dB≈2.5 mno outdoor unitoutdoor test only where there is an outdoor unitcalculated, MCS 020a, Q=2, no barrier
Cooling capacity2 kW——manufacturer-declared, EPREL

Sound at a neighbour's window

Each distance is one outdoor unit, Q=2, no barrier, scored against England and Wales at 37 dB(A).

Estimated sound pressure. Scotland's legal point is a different sum and is not this column.
DistanceFujitsu ASEH 2 kW (AOEH07KNCA) dB(A)Fujitsu ASEH 2 kW (AOEH07KNCA) vs 37 dBYolco TC (TC290) dB(A)Yolco TC (TC290) vs 37 dB
1 m45.0over——
2 m39.0over——
3 m35.5pass——
4 m33.0pass——
5 m31.0pass——
8 m27.0pass——
12 m23.4pass——

EPREL manufacturer-declared registrations · snapshot 25 Sep 2026 · n=2 · pair source tier is the weaker of the two cards; noise via contract_engine MCS 020a Q=2, no barrier · updated 25 Sep 2026 · version 1.0.0 · CSV of the values on this page

How this page was calculated

If the calculated sound pressure level at all assessment positions is equal to or lower than 37.0 dB(A) then the heat pump will comply with the Permitted Development noise limit Estimated by MCS 020a Issue 1.1 for one unit, Q=2, no barrier, via contract_engine. £ per summer is capacity ÷ SEER × hours × 26.32p/kWh (2026-10-01 to 2026-12-31). The pair row lives in the compare index CSV.

Better than a spec-sheet glance: the gap is scored at the same distances against the 37 dB line, and £ per summer uses one tariff.