Demmon DM (DM-6048-3A) vs ElectriQ EIQ 2.7 kW (EIQ-9WMINVEX-V5): which is quieter and cheaper to run?

ElectriQ EIQ 2.7 kW (EIQ-9WMINVEX-V5) is ≈50.0 dB(A) outside and passes England's 37 dB limit from 1.8 m; Demmon DM (DM-6048-3A) declares ≈64.0 dB(A) and has no outdoor unit. Pick Demmon DM (DM-6048-3A) if you need no outdoor unit — Class G does not apply; pick ElectriQ EIQ 2.7 kW (EIQ-9WMINVEX-V5) if the neighbour-window figure matters more.

manufacturer-declared, EPREL

37 dB(A) 1 m2 m3 m4 m5 m8 m12 m
Demmon DM (DM-6048-3A) and ElectriQ EIQ 2.7 kW (EIQ-9WMINVEX-V5), estimated dB(A).

Where the registered figures differ

The marker that opened this page: lwa, pass_distance. Both columns use the same tariff and the same noise setting.

Demmon DM (DM-6048-3A) against ElectriQ EIQ 2.7 kW (EIQ-9WMINVEX-V5). Difference is left minus right.
FieldDemmon DM (DM-6048-3A)ElectriQ EIQ 2.7 kW (EIQ-9WMINVEX-V5)DifferenceSource
Declared sound power64.0 dB(A)50.0 dB(A)+14.0 dBmanufacturer-declared, EPREL
SEER—8.9—manufacturer-declared, EPREL
SCOP—4.6—manufacturer-declared, EPREL
RefrigerantR290R290samemanufacturer-declared, EPREL
GWP33≈0 GWPmanufacturer-declared, EPREL
£ per summer, 400 h—£31.94—calculated: capacity ÷ SEER × 400 h × price-cap rate
Distance to pass 37 dBno outdoor unit≈1.8 moutdoor test only where there is an outdoor unitcalculated, MCS 020a, Q=2, no barrier
Cooling capacity—2.7 kW—manufacturer-declared, EPREL

Sound at a neighbour's window

Each distance is one outdoor unit, Q=2, no barrier, scored against England and Wales at 37 dB(A).

Estimated sound pressure. Scotland's legal point is a different sum and is not this column.
DistanceDemmon DM (DM-6048-3A) dB(A)Demmon DM (DM-6048-3A) vs 37 dBElectriQ EIQ 2.7 kW (EIQ-9WMINVEX-V5) dB(A)ElectriQ EIQ 2.7 kW (EIQ-9WMINVEX-V5) vs 37 dB
1 m——42.0over
2 m——36.0pass
3 m——32.5pass
4 m——30.0pass
5 m——28.0pass
8 m——24.0pass
12 m——20.4pass

EPREL manufacturer-declared registrations · snapshot 25 Sep 2026 · n=2 · pair source tier is the weaker of the two cards; noise via contract_engine MCS 020a Q=2, no barrier · updated 25 Sep 2026 · version 1.0.0 · CSV of the values on this page

How this page was calculated

If the calculated sound pressure level at all assessment positions is equal to or lower than 37.0 dB(A) then the heat pump will comply with the Permitted Development noise limit Estimated by MCS 020a Issue 1.1 for one unit, Q=2, no barrier, via contract_engine. £ per summer is capacity ÷ SEER × hours × 26.32p/kWh (2026-10-01 to 2026-12-31). The pair row lives in the compare index CSV.

Better than a spec-sheet glance: the gap is scored at the same distances against the 37 dB line, and £ per summer uses one tariff.