Daikin FVXM 2.4 kW (RXM25R / FVXM25A3V1B9) vs Olimpia Splendid OSSEACH 2.4 kW (OS-CEACH09EI): which is quieter and cheaper to run?

Olimpia Splendid OSSEACH 2.4 kW (OS-CEACH09EI) is ≈1.0 dB quieter outside (passes England's 37 dB limit from 4.0 m vs 4.5 m for Daikin FVXM 2.4 kW (RXM25R / FVXM25A3V1B9)); Daikin FVXM 2.4 kW (RXM25R / FVXM25A3V1B9) costs ≈£9.49 less per summer at 400 hours and 26.32p/kWh. Pick Olimpia Splendid OSSEACH 2.4 kW (OS-CEACH09EI) if the unit goes close to a neighbour's window; pick Daikin FVXM 2.4 kW (RXM25R / FVXM25A3V1B9) if running cost matters more.

manufacturer-declared, EPREL

37 dB(A) 1 m2 m3 m4 m5 m8 m12 m
Daikin FVXM 2.4 kW (RXM25R / FVXM25A3V1B9) and Olimpia Splendid OSSEACH 2.4 kW (OS-CEACH09EI), estimated dB(A).

Where the registered figures differ

The marker that opened this page: lwa, seer, scop, pass_distance. Both columns use the same tariff and the same noise setting.

Daikin FVXM 2.4 kW (RXM25R / FVXM25A3V1B9) against Olimpia Splendid OSSEACH 2.4 kW (OS-CEACH09EI). Difference is left minus right.
FieldDaikin FVXM 2.4 kW (RXM25R / FVXM25A3V1B9)Olimpia Splendid OSSEACH 2.4 kW (OS-CEACH09EI)DifferenceSource
Outdoor sound power58.0 dB(A)57.0 dB(A)+1.0 dBmanufacturer-declared, EPREL
SEER8.66.5+2.1 SEERmanufacturer-declared, EPREL
SCOP4.74.4+0.3 SCOPmanufacturer-declared, EPREL
RefrigerantR32R32samemanufacturer-declared, EPREL
GWP675675≈0 GWPmanufacturer-declared, EPREL
£ per summer, 400 h£29.38£38.87−£9.49calculated: capacity ÷ SEER × 400 h × price-cap rate
Distance to pass 37 dB≈4.5 m≈4.0 m+0.5 mcalculated, MCS 020a, Q=2, no barrier
Cooling capacity2.4 kW2.4 kW≈0 kWmanufacturer-declared, EPREL

Sound at a neighbour's window

Each distance is one outdoor unit, Q=2, no barrier, scored against England and Wales at 37 dB(A).

Estimated sound pressure. Scotland's legal point is a different sum and is not this column.
DistanceDaikin FVXM 2.4 kW (RXM25R / FVXM25A3V1B9) dB(A)Daikin FVXM 2.4 kW (RXM25R / FVXM25A3V1B9) vs 37 dBOlimpia Splendid OSSEACH 2.4 kW (OS-CEACH09EI) dB(A)Olimpia Splendid OSSEACH 2.4 kW (OS-CEACH09EI) vs 37 dB
1 m50.0over49.0over
2 m44.0over43.0over
3 m40.5over39.5over
4 m38.0over37.0pass
5 m36.0pass35.0pass
8 m32.0pass31.0pass
12 m28.4pass27.4pass

EPREL manufacturer-declared registrations · snapshot 25 Sep 2026 · n=2 · pair source tier is the weaker of the two cards; noise via contract_engine MCS 020a Q=2, no barrier · updated 25 Sep 2026 · version 1.0.0 · CSV of the values on this page

How this page was calculated

If the calculated sound pressure level at all assessment positions is equal to or lower than 37.0 dB(A) then the heat pump will comply with the Permitted Development noise limit Estimated by MCS 020a Issue 1.1 for one unit, Q=2, no barrier, via contract_engine. £ per summer is capacity ÷ SEER × hours × 26.32p/kWh (2026-10-01 to 2026-12-31). The pair row lives in the compare index CSV.

Better than a spec-sheet glance: the gap is scored at the same distances against the 37 dB line, and £ per summer uses one tariff.