UK home cooling

Home / Daikin FNA 6.8 kW (RZQG71L)

Daikin FNA 6.8 kW (RZQG71L) vs Fujitsu ARXG 6.8 kW (AOYG24KBT / ARXG24KHTAP): which is quieter and cheaper to run?

Daikin FNA 6.8 kW (RZQG71L) is ≈1.0 dB quieter outside (passes England's 37 dB limit from 8.9 m vs 10.0 m for Fujitsu ARXG 6.8 kW (AOYG24KBT / ARXG24KHTAP)); Fujitsu ARXG 6.8 kW (AOYG24KBT / ARXG24KHTAP) costs ≈£39.01 less per summer at 400 hours and 26.32p/kWh. Pick Daikin FNA 6.8 kW (RZQG71L) if the unit goes close to a neighbour's window; pick Fujitsu ARXG 6.8 kW (AOYG24KBT / ARXG24KHTAP) if running cost matters more.

manufacturer-declared, EPREL

37 dB(A) 1 m2 m3 m4 m5 m8 m12 m
Daikin FNA 6.8 kW (RZQG71L) and Fujitsu ARXG 6.8 kW (AOYG24KBT / ARXG24KHTAP), estimated dB(A).

Where the registered figures differ

The marker that opened this page: lwa, seer, scop, refrigerant, gwp, pass_distance. Both columns use the same tariff and the same noise setting.

Daikin FNA 6.8 kW (RZQG71L) against Fujitsu ARXG 6.8 kW (AOYG24KBT / ARXG24KHTAP). Difference is left minus right.
FieldDaikin FNA 6.8 kW (RZQG71L)Fujitsu ARXG 6.8 kW (AOYG24KBT / ARXG24KHTAP)DifferenceSource
Outdoor sound power64.0 dB(A)65.0 dB(A)−1.0 dBmanufacturer-declared, EPREL
SEER4.86.5−1.7 SEERmanufacturer-declared, EPREL
SCOP3.84.1−0.3 SCOPmanufacturer-declared, EPREL
RefrigerantR410AR32differentmanufacturer-declared, EPREL
GWP2088675+1413 GWPmanufacturer-declared, EPREL
£ per summer, 400 h£149.15£110.14+£39.01calculated: capacity ÷ SEER × 400 h × price-cap rate
Distance to pass 37 dB≈8.9 m≈10.0 m−1.1 mcalculated, MCS 020a, Q=2, no barrier
Cooling capacity6.8 kW6.8 kW≈0 kWmanufacturer-declared, EPREL

Sound at a neighbour's window

Each distance is one outdoor unit, Q=2, no barrier, scored against England and Wales at 37 dB(A).

Estimated sound pressure. Scotland's legal point is a different sum and is not this column.
DistanceDaikin FNA 6.8 kW (RZQG71L) dB(A)Daikin FNA 6.8 kW (RZQG71L) vs 37 dBFujitsu ARXG 6.8 kW (AOYG24KBT / ARXG24KHTAP) dB(A)Fujitsu ARXG 6.8 kW (AOYG24KBT / ARXG24KHTAP) vs 37 dB
1 m56.0over57.0over
2 m50.0over51.0over
3 m46.5over47.5over
4 m44.0over45.0over
5 m42.0over43.0over
8 m38.0over39.0over
12 m34.4pass35.4pass

EPREL manufacturer-declared registrations · snapshot 25 Sep 2026 · n=2 · pair source tier is the weaker of the two cards; noise via contract_engine MCS 020a Q=2, no barrier · updated 25 Sep 2026 · version 1.0.0 · CSV of the values on this page

How this page was calculated

If the calculated sound pressure level at all assessment positions is equal to or lower than 37.0 dB(A) then the heat pump will comply with the Permitted Development noise limit Estimated by MCS 020a Issue 1.1 for one unit, Q=2, no barrier, via contract_engine. £ per summer is capacity ÷ SEER × hours × 26.32p/kWh (2026-10-01 to 2026-12-31). The pair row lives in the compare index CSV.

Better than a spec-sheet glance: the gap is scored at the same distances against the 37 dB line, and £ per summer uses one tariff.

Report an error in these figures