Home / Argo ECOLIGHT 2.5 kW (ECOLIGHT9000UE / ECOLIGHT9000UI)

Argo ECOLIGHT 2.5 kW (ECOLIGHT9000UE / ECOLIGHT9000UI) vs Kingfisher International Products MSAFAU 2.5 kW (MOBA30-09HFN1-QRD0GW): which is quieter and cheaper to run?

Argo ECOLIGHT 2.5 kW (ECOLIGHT9000UE / ECOLIGHT9000UI) is registered with R32 (GWP 675); Kingfisher International Products MSAFAU 2.5 kW (MOBA30-09HFN1-QRD0GW) with R410A (GWP 2088). Pick Argo ECOLIGHT 2.5 kW (ECOLIGHT9000UE / ECOLIGHT9000UI) if its registered figures fit the room; pick Kingfisher International Products MSAFAU 2.5 kW (MOBA30-09HFN1-QRD0GW) if you want the other set.

EPREL registration, outdoor sound power not on one card

37 dB(A) 1 m2 m3 m4 m5 m8 m12 m
Argo ECOLIGHT 2.5 kW (ECOLIGHT9000UE / ECOLIGHT9000UI) and Kingfisher International Products MSAFAU 2.5 kW (MOBA30-09HFN1-QRD0GW), estimated dB(A).

Where the registered figures differ

The marker that opened this page: refrigerant, gwp. Both columns use the same tariff and the same noise setting.

Argo ECOLIGHT 2.5 kW (ECOLIGHT9000UE / ECOLIGHT9000UI) against Kingfisher International Products MSAFAU 2.5 kW (MOBA30-09HFN1-QRD0GW). Difference is left minus right.
FieldArgo ECOLIGHT 2.5 kW (ECOLIGHT9000UE / ECOLIGHT9000UI)Kingfisher International Products MSAFAU 2.5 kW (MOBA30-09HFN1-QRD0GW)DifferenceSource
Outdoor sound power60.0 dB(A)——manufacturer-declared, EPREL
SEER6.16.1≈0 SEERmanufacturer-declared, EPREL
SCOP4.04.0≈0 SCOPmanufacturer-declared, EPREL
RefrigerantR32R410Adifferentmanufacturer-declared, EPREL
GWP6752088−1413 GWPmanufacturer-declared, EPREL
£ per summer, 400 h£43.15£43.15≈£0calculated: capacity ÷ SEER × 400 h × price-cap rate
Distance to pass 37 dB≈5.6 m—one side still over 37 dB at 12 mcalculated, MCS 020a, Q=2, no barrier
Cooling capacity2.5 kW2.5 kW≈0 kWmanufacturer-declared, EPREL

Sound at a neighbour's window

Each distance is one outdoor unit, Q=2, no barrier, scored against England and Wales at 37 dB(A).

Estimated sound pressure. Scotland's legal point is a different sum and is not this column.
DistanceArgo ECOLIGHT 2.5 kW (ECOLIGHT9000UE / ECOLIGHT9000UI) dB(A)Argo ECOLIGHT 2.5 kW (ECOLIGHT9000UE / ECOLIGHT9000UI) vs 37 dBKingfisher International Products MSAFAU 2.5 kW (MOBA30-09HFN1-QRD0GW) dB(A)Kingfisher International Products MSAFAU 2.5 kW (MOBA30-09HFN1-QRD0GW) vs 37 dB
1 m52.0over——
2 m46.0over——
3 m42.5over——
4 m40.0over——
5 m38.0over——
8 m34.0pass——
12 m30.4pass——

EPREL manufacturer-declared registrations · snapshot 25 Sep 2026 · n=2 · pair source tier is the weaker of the two cards; noise via contract_engine MCS 020a Q=2, no barrier · updated 25 Sep 2026 · version 1.0.0 · CSV of the values on this page

How this page was calculated

If the calculated sound pressure level at all assessment positions is equal to or lower than 37.0 dB(A) then the heat pump will comply with the Permitted Development noise limit Estimated by MCS 020a Issue 1.1 for one unit, Q=2, no barrier, via contract_engine. £ per summer is capacity ÷ SEER × hours × 26.32p/kWh (2026-10-01 to 2026-12-31). The pair row lives in the compare index CSV.

Better than a spec-sheet glance: the gap is scored at the same distances against the 37 dB line, and £ per summer uses one tariff.